Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5649
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorJiménez Octavio, Jesús Ramónes-ES
dc.contributor.authorPilo De La Fuente, Eduardoes-ES
dc.contributor.authorEgido Cortés, Ignacioes-ES
dc.contributor.authorCarnicero López, Albertoes-ES
dc.date.accessioned2016-01-15T11:27:46Z-
dc.date.available2016-01-15T11:27:46Z-
dc.date.issued2007-12-05es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5649-
dc.descriptionCapítulos en libroses_ES
dc.description.abstractes-ES
dc.description.abstractThis paper introduces new criteria based on moving average of apparent power for sizing transformers in railway systems. Usually, transformers are designed to fulfill thermal criteria which are evaluated along several load cycles reported in the standards and literature. Nevertheless, real railway load cycles are quite variable and difficult to predict, therefore simulation techniques are necessary to estimate them. Detailed thermal studies require electric and thermal simulations for very particular operation, maintenance and climatic conditions. Hence these studies are focused on that special conditions and imply high computational costs too. To face this problem new sizing design criteria are proposed. These are based on the calculation of the moving average of the demand power, considering a time window which depends on the thermal time constant of the transformer. Finally, the results obtained with the proposed design criteria are discussed and compared with those obtained with the conventional hot-spot temperature based criterion.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherSin editorial (Pueblo, Estados Unidos de América)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: ASME/IEEE Joint Rail Conference and Internal Combustion Engine Division Spring Technical Conference - JRC/ICE 2007, Página inicial: 327-332, Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleNew transformer sizing criteria based on moving average techniques for railway systemses_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsNo disponible Not availableen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-07-008A.pdf300,86 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.