Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/5674
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Rondon, Daniel | es-ES |
dc.contributor.author | Vargas, Mauricio | es-ES |
dc.contributor.author | Herrera, Javier | es-ES |
dc.contributor.author | Montaña, Jhony | es-ES |
dc.contributor.author | Torres-Sánchez, Horacio | es-ES |
dc.contributor.author | Camargo, Martha | es-ES |
dc.contributor.author | Jiménez, Diana | es-ES |
dc.contributor.author | Delgadillo Vega, Andrés Ramiro | es-ES |
dc.date.accessioned | 2016-01-15T11:28:01Z | - |
dc.date.available | 2016-01-15T11:28:01Z | - |
dc.date.issued | 27/06/2005 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/5674 | - |
dc.description | Capítulos en libros | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | The aim of this paper is to implement different grounding system (GS) models in order to compare its influence on the calculation of overvoltages in transmission lines, produced by direct lightning strikes. The models studied were a lumped DC resistance, a non linear resistance, and a synthesized circuit based on the frequency response of the GS. The latest model is proposed by the authors and takes into account the frequency dependent transient behavior of the GS. The overvoltages simulations were carried out by means of the EMTP-ATP program. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.publisher | Sin editorial (San Petersburgo, Rusia) | es_ES |
dc.rights | es_ES | |
dc.rights.uri | es_ES | |
dc.source | Libro: 2005 IEEE Russia Power Tech, Página inicial: 1-6, Página final: | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Influence of grounding system modeling on Transient analysis of transmission lines due to direct lightning strike | es_ES |
dc.type | info:eu-repo/semantics/bookPart | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | EMTP/ATP, Grounding System, Lightning, Overvoltage. Transmission Line | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IIT-05-048A.pdf | 1,39 MB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.