Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5694
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorEchavarren Cerezo, Franciscoes-ES
dc.contributor.authorLobato Miguélez, Enriquees-ES
dc.contributor.authorRouco Rodríguez, Luises-ES
dc.contributor.authorNavarrete Fernández, María Isabeles-ES
dc.contributor.authorCasanova Lafarga, Rosaes-ES
dc.contributor.authorLópez, G.es-ES
dc.contributor.authorCacho, F.es-ES
dc.contributor.authorPézic, M.es-ES
dc.date.accessioned2016-01-15T11:28:11Z-
dc.date.available2016-01-15T11:28:11Z-
dc.date.issued2003-07-03es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5694-
dc.descriptionCapítulos en libroses_ES
dc.description.abstractes-ES
dc.description.abstractVoltage stability is concerned with the ability of a power system to maintain acceptable voltages at all buses. A measure of the power system voltage stability is the distance to the saddle node bifurcation of the power flow equations, which is called the load margin. Two approaches are widely used to compute the critical load margin: Continuation and Optimization. The first approach uses tangent vectors of the power flow equations to determine the saddle node bifurcation, whereas the second approach formulates it as a non-linear optimization problem. This paper reviews both algorithms, and proposes a method to combine both techniques, obtaining the load margin-voltages curves, and the sensitivities of the critical load margin with respect to the active and reactive power dispatch. Starting from an approximation of the saddle node bifurcation, calculated by continuation method, a least-squares problem is formulated to obtain an approximation of the Lagrange multipliers. This approximation will be used as starting point on critical load margin calculation by optimization method. The performance of the method is illustrated with the CIGRE 32-buses test system.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherSin editorial (Vilamoura, Portugal)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: 8ª Jornadas Hispano-Lusas de Ingeniería Eléctrica, Página inicial: , Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleA least-squares approach to estimate Lagrange multipliers in a combined method to voltages collapse detectiones_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsVoltage collapse, Critical load margin, Continuation power flow, Non-linearen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-03-025A.pdf146,69 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.