Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5741
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRouco Rodríguez, Luises-ES
dc.contributor.authorPagola y de las Heras, Francisco Luises-ES
dc.date.accessioned2016-01-15T11:28:35Z-
dc.date.available2016-01-15T11:28:35Z-
dc.date.issued2001-09-10es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5741-
dc.descriptionCapítulos en libroses_ES
dc.description.abstractes-ES
dc.description.abstractThis paper studies the sign of the feedback applied by Power System Damping Controllers (PSDCs). The sign of the feedback to be applied by power system stabilizers (PSSs) is well established from the understanding of the physical mechanisms of their damping action. However, the complexity of the damping action provided by FACTS devices does not allow to determine easily the sign of the feedback to be applied by their damping controllers. This paper discusses the sign of the feedback applied by PSDCs in the context of their design using eigenvalue sensitivities. As the eigenvalue sensivity approach to design PSDCs focus only on the poorly damped electromechanical modes, they can be properly damped whereas one or several unstable model may arise if the sign of the feedback s not proper. This paper suggest a criterion to determine the sign applied by PSDC's based on the analysis of the frequency response of the system transfer function seen by the controller combined with conclusions drawn from the numerical pole - zero analysis of the transfer functions of interest of several small power systems. The application of the criterion is illustrated in a small power system widely used for fundamental studies of power system electromechanical oscillationsen-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherSin editorial (Oporto, Portugal)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: IEEE Power Technology Conference, EDT5-345 EDT5-EMS/DMS TOOLS, Página inicial: , Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleOn the sign of the feedback applied by power system damping controllerses_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsPower system damping controllers, sign of feedback, eigenvalue sensitivitiesen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-01-034A.pdf744,66 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.