Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/66499
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Jauberteau, Jean Louis | es-ES |
dc.contributor.author | Jauberteau, Isabelle | es-ES |
dc.contributor.author | Cortázar Pérez, Osvaldo Daniel | es-ES |
dc.contributor.author | Megia Macías, Ana María | es-ES |
dc.date.accessioned | 2022-03-02T09:38:51Z | - |
dc.date.available | 2022-03-02T09:38:51Z | - |
dc.date.issued | 2022-01-01 | es_ES |
dc.identifier.issn | 0863-1042 | es_ES |
dc.identifier.uri | https:doi.org10.1002ctpp.202100066 | es_ES |
dc.description | Artículos en revistas | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | In low-temperature magnetized plasma, Langmuir probe measurements must be corrected because of the electron diffusion through the sheath, which is formed around the probe collector. The correction factor, which is called the electron diffusion or electron sink parameter, depends on many other parameters such as the probe geometry, the electron diffusion coefficient, the sheath thickness, or the potential profile through the sheath. Based on a previous work, we determine the values of this parameter under different experimental conditions and we study the effect of the electron energy, of the probe-biased voltage, and of the magnetic field intensity on this parameter. The results are compared with theoretical models published in the literature. An empirical equation is determined to fit the diffusion parameter value versus magnetic field intensity. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.rights | es_ES | |
dc.rights.uri | es_ES | |
dc.source | Revista: Contributions to Plasma Physics, Periodo: 1, Volumen: online, Número: 1, Página inicial: e202100066-1, Página final: e202100066-10 | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Langmuir probe in magnetized plasma: Study of the diffusion parameter | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | electron diffusion parameter, electron energy distribution function, Langmuir probe, magnetized plasma, plasma parameter | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IIT-22-021R.pdf | 723,99 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.