dc.description.abstractResearch into doubly-fed induction generator (DFIG) technology has yet to solve the instability that arises when DFIGs are connected to weak grids. To investigate this problem, this work used the modal analysis technique to study the impact of the phase-locked loop (PLL) control on the small-signal stability of wind-driven DFIGs and examine the sensitivity to the grid-impedance. Using a highly-detailed model, this study explains how stability can be guaranteed in terms of the ratio between the bandwidth of generator current controllers and the bandwidth of the phase-locked loop controller. Finally, the study provides practical recommendations for PLL design, based on the research findings.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherUniversidad de Castilla-La Mancha (Ciudad Real, España)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: 28º Seminario Anual de Automática, Electrónica industrial e Instrumentación - SAAEI 2021, Página inicial: 311-316, Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleImpact of PLL control on small-signal stability of wind DFIGs connected to weak gridses_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsWind generators, doubly fed induction generators, phase locked loop, modal analysis, eigenvalues.en-GB