Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/68049
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Gonzalez Sotres, Luis | es-ES |
dc.contributor.author | Mateo Domingo, Carlos | es-ES |
dc.contributor.author | Frías Marín, Pablo | es-ES |
dc.contributor.author | Rodríguez-Morcillo García, Carlos | es-ES |
dc.contributor.author | Matanza Domingo, Javier | es-ES |
dc.date.accessioned | 2022-05-05T14:54:14Z | - |
dc.date.available | 2022-05-05T14:54:14Z | - |
dc.date.issued | 2017-06-18 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/68049 | - |
dc.description | Capítulos en libros | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | Advanced Metering Infrastructures (AMI) represent one of the first steps in the Smart Grid process, where Power Line Communication (PLC) is emerging as the most costeffective solution since it allows reusing electric infrastructures as communication channel. However, the performance of this technology is highly affected by the characteristics of the existing distribution network. This article presents a thorough sensitivity analysis to assess the operating limits of smart metering applications for multiple representative configurations of low voltage (LV) networks based on a PLC simulation framework that integrates DLMSCOSEM and PRIME standards. The number of registered nodes and the time to read all meters have been defined as Key Performance Indicators to assess the communication performance. The conclusions drawn from this study provide useful information for the integration of smart meter applications that take advantage of AMI under different local conditions. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.publisher | Institute of Electrical and Electronics Engineers Power and Energy Society; University of Manchester (Mánchester, Reino Unido) | es_ES |
dc.rights | es_ES | |
dc.rights.uri | es_ES | |
dc.source | Libro: 12th IEEE PowerTech Conference - PowerTech 2017, Página inicial: 1-1, Página final: | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Replicability analysis of PLC PRIME networks for smart metering applications | es_ES |
dc.type | info:eu-repo/semantics/bookPart | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | smart meter, advance metering infrastructure (AMI), power line communications (PLC), PRIME, performance | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IIT-16-198A_abstract.pdf | 58,23 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.