Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/7432
Título : | Effect of combiined pllyometriic and ellectrostiimullatiion traiiniing on vertiicall jump |
Autor : | Benito Martínez, Elisa María Sánchez Lara, Amador Martinez Lopez, Emilio |
Fecha de publicación : | 6 |
Resumen : | En este estudio se han analizado los efectos del entrenamiento combinado de pliometría y electroestimulación
en un entrenamiento de fuerza muscular de los miembros inferiores. El estudio incluyó tres
grupos experimentales, que trabajaron ambos métodos en orden diferente y de forma simultánea, y
uno de control. Participaron 78 atletas, 40 mujeres y 38 hombres, de disciplinas de velocidad (100 y
200 m lisos y 100 y 110 m vallas), con una edad de 17,94 ± 1,44 años y una masa de 58,53 ± 8,05
kg. El programa incluyó dos días a la semana de entrenamiento pliométrico y dos sesiones utilizando
un electroestimulador Megasonic 313-P4. Tras dos meses de entrenamiento, se midió con plataforma
de contacto ORGANISER PSION 2 la altura de salto vertical y potencia del tren inferior en test de
Abalakov y Drop Jump. Las mayores diferencias pre/post test (p < 0.001) de altura y potencia de salto
se obtuvieron en el programa que realizó ejercicios pliométricos posteriores a la aplicación de la electroestimulación.
El entrenamiento de electroestimulación y pliometría llevado a cabo de forma simultánea
produjo un estancamiento en el rendimiento de los atletas. This paper analyses the effects of combined electrostimulation and plyometric training on lower body strength training. The training program was applied to three experimental groups and one control group. The experimental groups used both methods simultaneously but in different order. The participants were 78 sprinters (100m and 200m, and 100m and 110m hurdles), 38 male and 40 female. Their average age was 17,94 ± 1,4 years and their average weight was 58,53 ± 8,05kg. The training program consisted in two days a week of plyometric training and two sessions with a Megasonic 313-P4 electrostimulation unit. After two months training, vertical jump height and lower body power were measured in Abalakov and Drop Jump test with PSION ORGANISER II. The most significant pre- and post-test (p < 0.001) improvements in height and jump power were obtained in the program combining electrostimulation with subsequent plyometric exercises. Simultaneous electrostimulation and plyometric exercises caused performance stagnancy. |
Descripción : | Artículos en revistas |
URI : | http://hdl.handle.net/11531/7432 |
ISSN : | 1 8 8 5 - 3 1 3 7 |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
1º pagina.Rycide.pdf | 34,55 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.