Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/7695
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCamaño Gutiérrez, Isabeles-ES
dc.contributor.authorGarcía Burguillo, Antonioes-ES
dc.contributor.authorReneses Guillén, Javieres-ES
dc.contributor.authorVillar Ruiz, Olgaes-ES
dc.contributor.authorMontañez Quero, Doloreses-ES
dc.contributor.authorVallejo Pérez, Palomaes-ES
dc.date.accessioned2016-05-23T03:06:26Z-
dc.date.available2016-05-23T03:06:26Z-
dc.date.issued2011-09-01es_ES
dc.identifier.issn0304-5013es_ES
dc.identifier.urihttps://doi.org/10.1016/j.pog.2011.05.001es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractObjectivos: a) Estudiar la validez de la estimación ecográfica del peso fetal y determinar qué fórmula permite mejores predicciones. B) Proponer una fórmula que se adapte mejor a nuestra población. Material y métodos: Estudio prospectivo en el que se incluyen 282 gestaciones únicas a término. Determinación del peso fetal mediante 17 fórmulas. Análisis de su validez mediante el error medio y el porcentaje de predicciones con un error menor del 10%. Resultados: Catorce fórmulas presentaron un error medio menor del 10%. Diez de ellas permiten más de un 65% de predicciones válidas, con un error inferior al 10%. Las que ofrecen mejores resultados son algunas de las propuestas por Hadlock y la de Aoki. La fórmula propuesta, usando 3 parámetros ecográficos, permite un 73,8% de predicciones válidas con un error inferior al 10% y un 87,9% con un error inferior al 15%. Conclusiones: La estimación por eco 2D tiene una validez limitada. La fórmula propuesta mejora las estimaciones en nuestra población.es-ES
dc.description.abstract  Objective (a) To assess the validity of ultrasound estimation of fetal weight and to compare the accuracy of 17 sonographic formulae to predict fetal birth weight. (b) To propose a new formula that improves predictions in our population.   Methods We performed a prospective study that included 282 pregnant women at term. Seventeen formulae were used to predict fetal weight. To assess the accuracy of the predictions, the mean error and the percentage of estimations with a mean error of less than 10% were used.   Results Fourteen formulae provided a mean error lower than 10%. Ten of these formulae allowed estimations within ±10% of the actual birth weight in more that 65% of predictions. The most accurate formulae in predicting fetal weight were those of Hadlock and Aoki. With our formula, which employs three ultrasound parameters, 73.8% of estimations were valid with a mean error of 10% and 87.9% had an error of less than 15%.   Conclusions The accuracy of fetal weight estimation by ultrasound is limited and may improve with the new formula adjusted to our population.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoes-ESes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: Progresos de obstetricia y ginecología, Periodo: 1, Volumen: online, Número: 9, Página inicial: 452, Página final: 458es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleEstimación ecográfica del peso fetal: ¿podemos mejorar nuestras predicciones?es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsEstimación ecográfica; Peso fetal; Biometría fetales-ES
dc.keywordsen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-11-253A.pdf221,29 kBAdobe PDFVista previa
Visualizar/Abrir     Request a copy
IIT-11-253A_preview3,22 kBUnknownVisualizar/Abrir
IIT-11-253A_preview.pdf3,22 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.