Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/7904Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.contributor.author | Barquín Gil, Julián | es-ES |
| dc.contributor.author | Gómez San Román, Tomás | es-ES |
| dc.contributor.author | Pagola y de las Heras, Francisco Luis | es-ES |
| dc.date.accessioned | 2016-05-23T03:07:33Z | - |
| dc.date.available | 2016-05-23T03:07:33Z | - |
| dc.date.issued | 1995-11-01 | es_ES |
| dc.identifier.issn | 0885-8950 | es_ES |
| dc.identifier.uri | https://doi.org/10.1109/59.476063 | es_ES |
| dc.description | Artículos en revistas | es_ES |
| dc.description.abstract | This paper addresses the computation of the margin to the maximun power transfer limit. A non-linear \"sensitivity\" theory is presented and used to propose a new algorithm for this computation. The proposed algorithm is computationally efficient, allow a great variety of power system models, including reactive power output limits, and the optative consideration of heuristic knowledge about voltage collapse areas. The algorithm is tested in a 6-machines test system, a proposed benchmark system for voltage instability studies. | es-ES |
| dc.description.abstract | This paper addresses the computation of the margin to the maximun power transfer limit. A non-linear \"sensitivity\" theory is presented and used to propose a new algorithm for this computation. The proposed algorithm is computationally efficient, allow a great variety of power system models, including reactive power output limits, and the optative consideration of heuristic knowledge about voltage collapse areas. The algorithm is tested in a 6-machines test system, a proposed benchmark system for voltage instability studies. | en-GB |
| dc.format.mimetype | application/pdf | es_ES |
| dc.language.iso | en-GB | es_ES |
| dc.rights | es_ES | |
| dc.rights.uri | es_ES | |
| dc.source | Revista: IEEE Transactions on Power Systems, Periodo: 1, Volumen: online, Número: 4, Página inicial: 1952, Página final: 1962 | es_ES |
| dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
| dc.title | Estimating the loading limit taking into account voltage collapse areas | es_ES |
| dc.type | info:eu-repo/semantics/article | es_ES |
| dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
| dc.rights.holder | es_ES | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
| dc.keywords | Maximun power transfer, Voltage collapse, Margins | es-ES |
| dc.keywords | Maximun power transfer, Voltage collapse, Margins | en-GB |
| Aparece en las colecciones: | Artículos | |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| IIT-95-044R.pdf | 1,12 MB | Adobe PDF | ![]() Visualizar/Abrir Request a copy | |
| IIT-95-044R_preview | 2,47 kB | Unknown | Visualizar/Abrir | |
| IIT-95-044R_preview.pdf | 2,47 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.
