dc.description.abstractes-ES
dc.description.abstractTo address the reduction of system inertia, transmission system operators are now requesting converter-interfaced generators (CIGs) to participate in frequency support services. Microgrids (MGs) and virtual power plants have been used as a solution for aggregation of small CIGs. It has been recently considered they may use their combined actions to provide frequency services. However, these proposals are not general enough, focusing on specific CIGs controllers and, in many cases, stability and operational limits are not considered. This paper presents an standardised methodology to design MG controllers that are in compliance with the MG transient response specifications (frequency nadir and rate-of-change-of-frequency, ROCOF). The methodology has an iterative nature and can be applied when the network conditions change. In each iteration, the control parameters are adjusted based on the sensitivity of the system eigenvalues against the frequency metrics of interest while stability and operational constraints are respected. Compared to the literature, the use of quantitative parametric sensitivity is performed for the reallocation of several eigenvalues using two sensitivity components, not only one. Moreover, it is suitable for any combination of grid-forming and grid-following devices. The proposed methodology is applied to a benchmark MG and results show that both nadir and ROCOF can be effectively modified and set as required. The methodology was validated by using a real MG comprising four 15 kW converters and one 75 kW converter.en-GB
dc.format.mimetypeapplication/octet-streames_ES
dc.language.isoen-GBes_ES
dc.sourceRevista: International Journal of Electrical Power & Energy Systems, Periodo: 1, Volumen: online, Número: Part B, Página inicial: 109539-1, Página final: 109539-11es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleCoordination of distributed resources for frequency support provision in microgridses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordses-ES
dc.keywordsMicrogrid; Inertia; Grid-forming; Nadir; ROCOF; Small-signal analysisen-GB