Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/87086
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCastrillo, Gabrieles-ES
dc.contributor.authorCarnicero López, Albertoes-ES
dc.contributor.authorPerera Velamazan, Ricardoes-ES
dc.date.accessioned2024-02-23T13:34:36Z-
dc.date.available2024-02-23T13:34:36Z-
dc.date.issued2023-02-01es_ES
dc.identifier.issn2040-7939es_ES
dc.identifier.urihttps:doi.org10.1002cnm.3672es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractThanks to new digital technologies, complex cases of severe maxillary atrophy may now be treated with additively manufactured subperiosteal implant structures (AMSISs). However, there are few studies addressing this topic and most of them focus on the mechanical behaviour of the AMSIS itself without considering its interaction with the maxilla bone. The aim of this study is to provide a methodology based on finite element analysis (FEA) to evaluate the effect of interaction between the maxilla bone and the screws fixing the AMSIS. The mechanical performance of an AMSIS was examined via a FEA based on submodelling. Significant differences were encountered in displacements and reaction forces when bone–screw interaction was considered. Stress in the cortical layer was found to be close to the maximum strength while the trabecular layer seems to have no effect on the results; stresses in the AMSIS are lower than the fatigue stress limit. Finally, the comparison of stresses between models with and without osseointegration shows how stresses drop once osseointegration is complete. The proposed submodelling approach considerably reduces the computational effort and enables both a detailed model of the interaction between the thread of the screws and the bone and an accurate evaluation of displacement and stress fields on the interface. The results have shown that stresses in the cortical bone are highly affected by the initial geometry of the thread inside the bone, which demonstrates the importance of modelling the effect of the thread.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: International Journal for Numerical Methods in Biomedical Engineering, Periodo: 1, Volumen: online, Número: 2, Página inicial: e3672-1, Página final: e3672-16es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleSubmodelling approach to screw-to-bone interaction in additively manufactured subperiosteal implant structureses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsad hoc prosthesis, AMSIS, dental implant, finite element method, screw-to-bone contact, submodelling, subperiosteal implant structuresen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
IIT-22-267R.pdf4,54 MBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.