Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/87110
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Alonso Rivas, Eduardo | es-ES |
dc.contributor.author | Giannetti, Romano | es-ES |
dc.contributor.author | Rodríguez-Morcillo García, Carlos | es-ES |
dc.contributor.author | Matanza Domingo, Javier | es-ES |
dc.contributor.author | Muñoz Frías, José Daniel | es-ES |
dc.contributor.author | Scandurra, Graziella | es-ES |
dc.contributor.author | Ciofi, Carmine | es-ES |
dc.contributor.author | Vega Zelaya, Lorena | es-ES |
dc.contributor.author | Pastor, Jesús | es-ES |
dc.date.accessioned | 2024-02-23T13:37:25Z | - |
dc.date.available | 2024-02-23T13:37:25Z | - |
dc.date.issued | 2022-12-01 | es_ES |
dc.identifier.issn | 2079-9292 | es_ES |
dc.identifier.uri | https:doi.org10.3390electronics11233918 | es_ES |
dc.description | Artículos en revistas | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | Intraoperative Neurophysiological Monitoring is a set of monitoring techniques that reads electrical activity generated by the nervous system structures during surgeries. In non-trivial surgeries, neurophysiologists require a significant number of electrical signals to be picked up to check the effects of the surgeon’s actions in real time or to confirm that the correct nerves are selected. As a result, cabling the patient in the operating room can become cumbersome. The proposed WIONM module solves part of the problem by converting a good part of those cables into a wireless connection that is substantially transparent to the human operator and the existing medical instrumentation. | en-GB |
dc.format.mimetype | application/octet-stream | es_ES |
dc.language.iso | en-GB | es_ES |
dc.source | Revista: Electronics, Periodo: 1, Volumen: online, Número: 23, Página inicial: 3918-1, Página final: 3918-19 | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | A quasi-wireless intraoperatory neurophysiological monitoring system | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.holder | es_ES | |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | intraoperative monitoring; ECG; EMG; EEG; MEP; SSEP; AEP; wireless | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Tamaño | Formato | |
---|---|---|---|
A%20quasi-wireless%20intraoperatory%20neurophysiological%20monitoring%20system | 9,53 MB | Unknown | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.