Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/96225
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorHerrera Martín, Ángeles-ES
dc.contributor.authorAzabal, Magdalenaes-ES
dc.contributor.authorJiménez Octavio, Jesús Ramónes-ES
dc.contributor.authordel Real Romero, Juan Carloses-ES
dc.contributor.authorLópez de Armentia Hernández, Saraes-ES
dc.contributor.authorAsensio Gil, Juan Manueles-ES
dc.contributor.authorArias Paniagua, Ana Maríaes-ES
dc.date.accessioned2024-11-25T16:46:54Z-
dc.date.available2024-11-25T16:46:54Z-
dc.date.issued2024-08-02es_ES
dc.identifier.issn1996-1944es_ES
dc.identifier.urihttps:doi.org10.3390ma17163978es_ES
dc.identifier.urihttp://hdl.handle.net/11531/96225-
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractThis study assessed the surface topography and plastic deformation (PD) of new and used contemporary reciprocating instruments. Twenty-six WaveOne Gold (WOG) and EdgeOne Fire (EO) instruments were photographed under magnification. The instruments were randomly assigned to a control group of new instruments preserved for surface roughness analysis (n = 6 each), or to an experimental group to shape the root canal system of a single molar (n = 20 each), making a total of four groups (WOGnew, EOnew, WOGused, EOused). Used instruments were also photographed after instrumentation. The presence of fractures was registered. Preoperative and postoperative images were randomly ordered for evaluation. Two blinded calibrated examiners evaluated the presence of PD. Inter-observer agreement was calculated with the Kappa coefficient (K = 0.89). 3D profilometry was also used for the surface roughness analysis of six randomly selected instruments from the WOGused and EOused groups. Chi-square and two-way ANOVA tests were used to, respectively, compare PD and changes in surface roughness among the groups. No instruments fractured; however, a significantly greater percentage of EO instruments suffered plastic deformation than WOG instruments (p < 0.001), (OR = 11.09 (CI 95 2.6–56.3)). The overall surface roughness was higher for most parameters in the EO instruments (p < 0.05). Single uses of EO instruments produced significantly higher chances of PD and increased surface roughness values compared to WOG.en-GB
dc.format.mimetypeapplication/octet-streames_ES
dc.language.isoen-GBes_ES
dc.sourceRevista: Materials, Periodo: 1, Volumen: online, Número: 16, Página inicial: 3978-1, Página final: 3978-12es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleComparative analysis of surface roughness and plastic deformation of reciprocating instruments after clinical usees_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordses-ES
dc.keywordssurface roughness; WaveOne gold; EdgeOne fire; profilometry; plastic deformation; nickel–titanium; root canal preparation; Ni-Ti fileen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
IIT-24-241R2,47 MBUnknownVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.