Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/97771
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorLobato Miguélez, Enriquees-ES
dc.contributor.authorSánchez Martín, Pedroes-ES
dc.contributor.authorRajabdorri, Mohammades-ES
dc.contributor.authorSigrist, Lukases-ES
dc.date.accessioned2025-03-04T18:08:22Z-
dc.date.available2025-03-04T18:08:22Z-
dc.date.issued2024-08-08es_ES
dc.identifier.urihttp://hdl.handle.net/11531/97771-
dc.descriptionCapítulos en libroses_ES
dc.description.abstractes-ES
dc.description.abstractUnit commitment (UC) models used in real-life island power systems (IPSs) require complex modelling details and low execution times since they have to be launched repeated times for different assumptions and changing conditions. For this reason, system operators and power generation companies discard for daily analysis sophisticated models such as stochastic, robust or frequency-constrained UC. Instead, they prioritize the use of deterministic standard UC (STUC), where units are scheduled imposing a static reserve criterion such that the amount of available spinning reserve is sufficient to cover expected disturbances. This paper outlines why in IPSs the spinning reserve requirement increments dramatically the computational burden of a STUC, proposing practical solutions to contain runtimes. Proposed solutions include incrementing convergence tolerance, dividing a weekly optimization in seven sequential daily problems and formulating alternative equations for the reserve constraints. Results of real-life small and big size Spanish IPS will demonstrate how execution times are drastically diminished with acceptable loss of accuracy.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherKadir Has Üniversitesi (Estambul, Turquía)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: 20th International Conference on the European Energy Market - EEM24, Página inicial: 1-6, Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titlePractical solutions to limit computational burden of UC in Island Power Systemses_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsisland power systems, unit commitment, frequency stabilityen-GB