Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/97787
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRouco Rodríguez, Luises-ES
dc.contributor.authorArchilla Martín-Sanz, Jacoboes-ES
dc.contributor.authorGavilán Moreno, Carloses-ES
dc.date.accessioned2025-03-04T18:12:23Z-
dc.date.available2025-03-04T18:12:23Z-
dc.date.issued2022-11-28es_ES
dc.identifier.urihttp://hdl.handle.net/11531/97787-
dc.descriptionCapítulos en libroses_ES
dc.description.abstractes-ES
dc.description.abstractUnited States Nuclear Regulatory Commission (US NRC) has requested to the US nuclear power generating industry that Open Phase Conditions (OPCs) should be automatically detected. This requirement has been extended by other regulatory bodies worldwide. Several systems for detecting OPCs are available in the marketplace. Remote open phase faults in the supply system of start-up transformers of nuclear power generating stations (NPGSs) pose a major challenge for available detection systems. A remote fault consists of an open phase fault in an intermediate point of the transmission line that feeds the startup transformer of the NPGS. This paper investigates the ability of existing methods to detect a remote open phase fault in the transmission line that feeds the start-up transformer of a NPGS.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherInstitute of Electrical and Electronics Engineers Power and Energy Society; Consejo Internacional de (Bayona, España)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: 7th International Advanced Research Workshop on transformers - ARWtr 2022, Página inicial: 1-6, Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleRemote open phase faults in the start-up transformers of a nuclear power generating stationes_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsOpen phase faults, Nuclear power generating stations, Unit Auxiliary transformer, Station start-up transformer, Symmetrical component analysisen-GB