Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/97787
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Rouco Rodríguez, Luis | es-ES |
dc.contributor.author | Archilla Martín-Sanz, Jacobo | es-ES |
dc.contributor.author | Gavilán Moreno, Carlos | es-ES |
dc.date.accessioned | 2025-03-04T18:12:23Z | - |
dc.date.available | 2025-03-04T18:12:23Z | - |
dc.date.issued | 2022-11-28 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/97787 | - |
dc.description | Capítulos en libros | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | United States Nuclear Regulatory Commission (US NRC) has requested to the US nuclear power generating industry that Open Phase Conditions (OPCs) should be automatically detected. This requirement has been extended by other regulatory bodies worldwide. Several systems for detecting OPCs are available in the marketplace. Remote open phase faults in the supply system of start-up transformers of nuclear power generating stations (NPGSs) pose a major challenge for available detection systems. A remote fault consists of an open phase fault in an intermediate point of the transmission line that feeds the startup transformer of the NPGS. This paper investigates the ability of existing methods to detect a remote open phase fault in the transmission line that feeds the start-up transformer of a NPGS. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.publisher | Institute of Electrical and Electronics Engineers Power and Energy Society; Consejo Internacional de (Bayona, España) | es_ES |
dc.rights | es_ES | |
dc.rights.uri | es_ES | |
dc.source | Libro: 7th International Advanced Research Workshop on transformers - ARWtr 2022, Página inicial: 1-6, Página final: | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Remote open phase faults in the start-up transformers of a nuclear power generating station | es_ES |
dc.type | info:eu-repo/semantics/bookPart | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | Open phase faults, Nuclear power generating stations, Unit Auxiliary transformer, Station start-up transformer, Symmetrical component analysis | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Tamaño | Formato | |
---|---|---|---|
IIT-22-115C.pdf | 393,17 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.