Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/97804| Título : | Optimal degree of smart transformer substations in distribution networks for reliability improvement |
| Autor : | Rodríguez Calvo, Andrea Frías Marín, Pablo Reneses Guillén, Javier Mateo Domingo, Carlos |
| Fecha de publicación : | 21-feb-2013 |
| Editorial : | Sin editorial (Berlín, Alemania) |
| Resumen : | The medium to low voltage transformer substation is a key element in the distribution system. Therefore, smart transformer substations will play a crucial role in the evolution of distribution towards the smart grid. Smart transformer substations can provide a significant improvement of continuity of supply. However, a large investment is required, so the optimal degree of automation must be determined. The main objective of this paper is to quantify the impact of smart MV/LV transformer substations on continuity of supply, which is essential to determine the optimal automation degree. The analysis has considered different degrees of implementation of smart MV/LV substations for different configuration schemes of urban distribution networks. Furthermore, sensitivity analyses have been performed for the main parameters involved so that conclusions on reliability improvement achieved by MV/LV transformer substation automation can be scaled up. The medium to low voltage transformer substation is a key element in the distribution system. Therefore, smart transformer substations will play a crucial role in the evolution of distribution towards the smart grid. Smart transformer substations can provide a significant improvement of continuity of supply. However, a large investment is required, so the optimal degree of automation must be determined. The main objective of this paper is to quantify the impact of smart MV/LV transformer substations on continuity of supply, which is essential to determine the optimal automation degree. The analysis has considered different degrees of implementation of smart MV/LV substations for different configuration schemes of urban distribution networks. Furthermore, sensitivity analyses have been performed for the main parameters involved so that conclusions on reliability improvement achieved by MV/LV transformer substation automation can be scaled up. |
| Descripción : | Capítulos en libros |
| URI : | http://hdl.handle.net/11531/97804 |
| Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
| Fichero | Tamaño | Formato | |
|---|---|---|---|
| IIT-12-082A.pdf | 467,83 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.