• English
    • español
  • español 
    • English
    • español
  • Login
Ver ítem 
  •   DSpace Principal
  • 1.- Docencia
  • Enfermería y Fisioterapia
  • Máster Universitario en Biomecánica aplicada a la Valoración del Daño; Técnicas Avanzadas en Fisioterapia
  • H24-Trabajos Fin de Máster
  • Ver ítem
  •   DSpace Principal
  • 1.- Docencia
  • Enfermería y Fisioterapia
  • Máster Universitario en Biomecánica aplicada a la Valoración del Daño; Técnicas Avanzadas en Fisioterapia
  • H24-Trabajos Fin de Máster
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Estudio piloto de fiabilidad interexaminador del test de gilletliekens/stork test/spine test estableciendo unas referencias anatómicas fijas y utilizando un sistema de captura de movimiento como soporte de objetivación

Thumbnail
Ver/
Proyecto Fin de Máster (1.846Mb)
Autorización (573.5Kb)
Fecha
2012
Autor
Lois Gutiérrez, Sandra Olga
Director/Coordinador
Pérez Mallada, Néstor
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
Antecedentes: El Test de Gillet-Liekens es uno de los métodos diagnósticos más utilizados para el estudio de las disfunciones en la articulación sacroilíaca. Sin embargo, su fiabilidad es baja y diversos autores recomiendan investigar más sobre las causas. Un factor determinante puede ser la falta de consenso en la localización de las referencias anatómicas. Objetivo: Identificar si el error inducido en la localización de las referencias anatómicas es la causa de la escasa fiabilidad que presenta el Test de Gillet, utilizando un sistema optoeléctrico como soporte biomecánico de objetivación. Metodología: Estudio piloto comparativo de concordancia de un test diagnóstico con estrategia de evaluador ciego. Se tomará una muestra de 30 sujetos y se les realizará el test en tres ocasiones consecutivas. El primer test lo llevará a cabo un examinador experimentado, seguido de un examinador que, mediante un sistema optoeléctrico, objetivará los hallazgos del segundo test. En tercer lugar, otro examinador llevará a cabo el mismo test utilizando como referencias anatómicas los lugares exactos en los que se colocaron los marcadores reflectantes del sistema optoeléctrico en el segundo test. Se hará un estudio del índice de concordancia Kappa de Cohen.
 
Background: The Gillet-Liekens Test is one of the most used diagnostic methods for the study of the sacroiliac joint dysfunctions. However, its reliability seems to be low and several authors recommend doing more research about the causes. A key factor could be the lack of agreement in the localization of the anatomical references. Objective: Identify if the error in the anatomical references localization might be the cause of the low reliability shown by the Gillet Test, using an optoelectric system as a biomechanical objectifying support. Methodology: Comparative concordance pilot study of a diagnostic test with a blind evaluator strategy. A sample of 30 subjects will be taken, to whom we will perform the test three times in a row. The first test will be performed by an experienced examiner, followed by another examiner that will be using the optoelectric system in order to objectify the discoveries of the second test. Thirdly, another examiner will perform the same test using as anatomical references the exact places in which the reflectant markers of the optoelectric system were placed during the second test. A study of the Cohen’s Kappa Index will be done.
 
URI
http://hdl.handle.net/11531/26690
Trabajo Fin de Máster
Estudio piloto de fiabilidad interexaminador del test de gilletliekens/stork test/spine test estableciendo unas referencias anatómicas fijas y utilizando un sistema de captura de movimiento como soporte de objetivación
Titulación / Programa
Titulación::Postgrado::Máster Universitario en Biomecánica aplicada a la Valoración del Daño; Técnicas Avanzadas en Fisioterapia
Materias/ UNESCO
UNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapia
UNESCO::32 Medicina::3213 Cirugía::321315 Traumatología
Palabras Clave
Test De Gillet-Liekens, Articulación Sacroilíaca, Fiablilidad, Kappa de Cohen, Sistema Optoeléctrico
Gillet-Liekens Test, Sacroiliac joint, Reliability, Cohen’s Kappa, Optoelectric system
Colecciones
  • H24-Trabajos Fin de Máster

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias