Mostrar el registro sencillo del ítem

dc.contributor.authorCledera Castro, Mª del Mares-ES
dc.contributor.authorSantos Montes, Ana Maríaes-ES
dc.contributor.authorIzquierdo Hornillos, Robertoes-ES
dc.date.accessioned2016-01-15T11:19:38Z
dc.date.available2016-01-15T11:19:38Z
dc.date.issued01/01/2006es_ES
dc.identifier.issn1471-6577es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5322
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractAn isocratic HPLC method for the determination of phenol and nitrophenols (4-nitrophenol, 2-nitrophenol, 4,6-dinitro-o-cresol and 2,4-dinitrophenol) has been developed and validated using 2-chlorophenol as internal standard (IS) and a monolithic column in tap water samples. Prior to HPLC, the method requires solid-phase extraction (SPE) using polymeric Lichrolut EN cartridges. The method development involved the study of methanol and acetonitrile as organic modifiers, pH and flow-rate using a Chromolith RP-18e (150 mm × 4.6 mm I.D.) column. After comparing the performance of the separations obtained with both organic modifiers, the optimum separation of these compounds was achieved using 50 mM acetate buffer (pH 5.0)-acetonitrile (80:20, v/v) as mobile phase, 3 mL min-1 flow-rate and UV detection at maximum absorbance wavelength. Under these conditions, all analytes were separated (Rs > 2.0) in an analysis time of less than 3.5 min and the most important validation parameters were evaluated. The recoveries obtained in the accuracy test for all phenols studied were in the 90 112\% range using a preconcentration factor of 40, and the intraday and interday precisions [expressed as coefficient of variation (CV)] were smaller than 15\%. Finally, the proposed method was applied to wastewater samples from several industries.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: LC-GC Europe, Periodo: 1, Volumen: 19, Número: 7, Página inicial: 424, Página final: 431es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleMethod Development and Validation for Phenol and Nitrophenols in Tap Water by HPLC using a Monolithic Columnes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsen-GB


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem