JavaScript is disabled for your browser. Some features of this site may not work without it.

Vibration monitoring of electric generators without sensor dedicated

Thumbnail
Ver/
IIT-10-002A.pdf (985.1Kb)
Fecha
2010-05-27
Autor
Vieira Junior, Petronio
Sanz Bobi, Miguel Ángel
Ruiz Gomes, Cristiane
Simoes Gomes, Hermínio
Pacheco do Nascimento, Miguel
Estado
info:eu-repo/semantics/publishedVersion
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
 
 
This paper describes a method for on-line condition monitoring of rotating electric generators without a need for installed sensors dedicated. This sensorless method has been based on continuous monitoring vibration using neural networks for the classification of bearing failures experimentally induced. The results obtained have an error of less than 0,5 confirming the validity of the method proposed.
 
URI
http://hdl.handle.net/11531/5613
Vibration monitoring of electric generators without sensor dedicated
Tipo de Actividad
Capítulos en libros
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave


Colecciones
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias