• English
    • español
  • English 
    • English
    • español
  • Login
View Item 
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Power oscillation damping method suitable for network reconfigurations based on converter interfaced generation and combined use of active and reactive powers

Thumbnail
View/Open
Power%20oscillation%20damping%20method%20suitable%20for%20network%20reconfigurations%20based%20on%20converter%20interfaced%20generation%20and%20combined%20use%20of%20active%20and%20reactive%20powers (1.306Mb)
Date
2023-07-01
Author
Jankovic, Njegos
Roldan Perez, Javier
Prodanovic, Milan
Suul, Jon Are
D'Arco, Salvatore
Rouco Rodríguez, Luis
Estado
info:eu-repo/semantics/publishedVersion
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
 
 
Power system stabilisers (PSSs) are commonly used in synchronous generators for damping low-frequency oscillations. However, many of these machines have been replaced by converter-interfaced generators (CIGs), such as those used in solar power plants. This means that CIG-based power plants should also contribute to oscillation damping. Moreover, CIGs may use both active and reactive power for power oscillation damping (POD). However, their combined use has been seldom studied in the literature. Moreover, only a few articles have addressed the adaption of POD controllers when the power system changes (e.g., after a fault). In this paper, a POD controller for CIG-based power plants is proposed that is suitable for operation in power systems exposed to reconfiguration. This controller takes advantage of both active and reactive power injection to maximise the damping of the power system. This controller is based only on local measurements so communication systems are not required. Theoretical developments were validated in a laboratory using real power converters including a 75 kVA grid emulator where the two-area benchmark model is emulated and four 15 kVA CIGs operating in parallel connection. The applicability of the proposed controller was also explored for the IEEE 39-bus system.
 
URI
https:doi.org10.1016j.ijepes.2023.109010
Power oscillation damping method suitable for network reconfigurations based on converter interfaced generation and combined use of active and reactive powers
Tipo de Actividad
Artículos en revistas
ISSN
0142-0615
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave

Power oscillation damping; Low-frequency oscillations; Power modulation; Network reconfiguration; Power oscillation damping controller
Collections
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback