• Aportaciones fisiológicas de la medida continua de la saturación de oxígeno en atletas de ambos sexos que realizan pruebas de esfuerzo máximas 

      Martín Escudero, Pilar; Miguel-Tobal, Francisco; Bilbao Monasterio, Amaya; Galindo Canales, Mercedes; Silveira Martín, Juan Pedro; Dotor Castilla, María Luisa; Golmayo Fernández, Dolores; Giannetti, Romano; López-Silva, Sonnia María (2006-10-01)
      El objetivo de este estudio se centra en la monitorización continua de la saturación de oxígeno en sangre en deportistas durante la realización de una prueba de esfuerzo máxima. El conocimiento de la evolución de la ...
    • Are activity wrist-worn devices accurate for determining heart rate during intense exercise? 

      Martín Escudero, Pilar; Cabanas Plana, Ana Maria; Dotor Castilla, María Luisa; Galindo Canales, Mercedes; Miguel Tobal, Francisco; Fernández Pérez, Cristina; Fuentes Ferrer, Manuel; Giannetti, Romano (2023-02-01)
      The market for wrist-worn devices is growing at previously unheard-of speeds. A consequence of their fast commercialization is a lack of adequate studies testing their accuracy on varied populations and pursuits. To provide ...
    • Are activity wrist-worn devices accurate for determining heart rate during intense exercise? 

      Martín Escudero, Pilar; Cabanas Plana, Ana Maria; Dotor Castilla, María Luisa; Galindo Canales, Mercedes; Miguel Tobal, Francisco; Fernández Pérez, Cristina; Fuentes Ferrer, Manuel; Giannetti, Romano (15/02/2023)
      The market for wrist-worn devices is growing at previously unheard-of speeds. A consequence of their fast commercialization is a lack of adequate studies testing their accuracy on varied populations and pursuits. To provide ...
    • Heuristic algorithm for photoplethysmographic heart rate tracking during maximal exercise test 

      López-Silva, Sonnia María; Giannetti, Romano; Dotor Castilla, María Luisa; Silveira, J.; Golmayo Fernández, Dolores; Miguel-Tobal, Francisco; Bilbao Monasterio, Amaya; Galindo Canales, Mercedes; Martín Escudero, Pilar (2012-07-01)
      Photoplethysmography (PPG) is a non-invasive optical technique that can be used to quantify the arterial blood pulse rate. Signal corruption by motion artifacts limits the practical accuracy and applicability of instruments ...
    • Oxygen saturation through pulse oximetry in sportswomen 

      Martín Escudero, Pilar; Miguel-Tobal, Francisco; Dotor Castilla, María Luisa; López-Silva, Sonnia María; Giannetti, Romano; Galindo Canales, Mercedes
      Oximetry is a method used to assess peripheral blood oxygen saturation based on the determination of the level of red light absorption, directly influenced by the hemoglobin levels. Most studies on pulse oximetry, within ...
    • Pulse rate measurement from transmittance photoplethysmography in cycle ergometer test 

      López-Silva, Sonnia María; Dotor Castilla, María Luisa; Silveira, J.; Giannetti, Romano; Miguel-Tobal, Francisco; Bilbao Monasterio, Amaya; Galindo Canales, Mercedes; Martín Escudero, Pilar (IEEE (Austin, Estados Unidos de América), 2010-05-03)
      Photoplethysmography (PPG) is a non-invasive optical technique that enables to quantify the arterial blood pulse rate derived from the cardiac pumping action. Although this technique is widely used in the medical practice ...