Co-Optimizing Synthetic and Synchronous Inertia in Frequency-Constrained Unit Commitment: A Case Study on La Palma

Thumbnail
Ver/
IIT-26-195C.pdf (489.9Kb)
Autor
Olasoji, Azeez O.
Oyedokun, David T.O.
Adeyinka, Adebayo Victor
Rajabdorri, Mohammad
Sierra Aguilar, Juan Esteban
Ajayi-Obey, Akinola
Aluko-Olokun, Pelumi Peter
Estado
info:eu-repo/semantics/draft
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
 
 
High penetrations of converter-interfaced renewable energy sources (RES) are eroding synchronous inertia in many power systems, making frequency security a binding constraint in unit commitment (UC), especially for weak island grids. This paper develops an analytical frequency-constrained unit commitment (FCUC) formulation that (i) co-optimises synchronous inertia and synthetic inertia (SI) from wind power plants and (ii) supports both classical DC power-flow and PTDF-based linear sensitivity factor (LSF) network representations within a unified mixed-integer linear programming (MILP) framework. The frequency nadir constraints is enforced via a separable-programming approximation that remains fully MILP-compatible. The model is validated on the real La Palma island system. Results show that, under an unconstrained network (transmission-capacity factor TCF =1.0), varying the emulated inertia constant kem  between 0 s and 6 s has negligible impact on total cost, renewable spillage, and frequency-security indicators: RoCoF remains orders of magnitude below its limit and the nadir constraint is numerically binding in all cases. A comparison between DC and LSF formulations confirms that the LSF model closely reproduces the DC dispatch and frequency metrics while achieving smaller optimality gaps. A subsequent TCF evaluation shows that tightening transmission limits only becomes economically material at TCF=0.6, where costs rise and a small amount of RES curtailment appears, without compromising RoCoF or nadir security. Overall, the results demonstrate that SI from wind can be co-optimised with synchronous inertia and LSF-based transmission constraints in a single tractable FCUC model, providing a structured way to assess inertia provision, wind utilisation, and congestion management in low-inertia island grids.
 
URI
http://hdl.handle.net/11531/110937
Co-Optimizing Synthetic and Synchronous Inertia in Frequency-Constrained Unit Commitment: A Case Study on La Palma
Palabras Clave

Frequency-constrained unit commitment (FCUC), synthetic inertia (SI), wind power, renewable energy
Colecciones
  • Documentos de Trabajo

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias