Damping local and inter-area oscillations with synchronous compensators: a fundamental study

Thumbnail
Ver/
IIT-24-156C.pdf (412.9Kb)
Autor
Rouco Rodríguez, Luis
Suárez Porras, Jorge
Fernández Bernal, Fidel
Sigrist, Lukas
Estado
info:eu-repo/semantics/draft
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
 
 
The increase in the penetration of inverter-based generation in current power systems is reducing their short circuit currents and inertia. Synchronous compensators are being proposed and installed to address those issues. Recent events in the Continental European system have shown that the security of the power system may be at risk due to poorly damped inter-area oscillations. Synchronous compensators have also been proposed to damp electromechanical oscillations.This paper contains a fundamental study of the contribution of synchronous compensators to damping local and inter-area oscillations based on eigenvalue analysis of the small-signal model of simple power system models.Three power system models are considered. The first power system consists of a synchronous compensator connected to an infinite bus through its step-up transformer and a transmission line. The eigenvalue analysis shows that the electromechanical oscillation of the synchronous compensator cannot be affected by a power system stabilizer (PSS).The second power system consists of a synchronous generator in parallel with a synchronous compensator. The eigenvalue analysis confirms that although the joint electromechanical oscillation of both synchronous machines against the infinite grid can be damped by installing a PSS in the synchronous compensator, the most effective location of the PSS is the synchronous generator.The third power system is aimed at assessing the impact of synchronous compensators in the damping of inter-area oscillations in the presence of inverter-based generation. The eigenvalue analysis of the third power system shows that the synchronous compensator should be equipped with a PSS.
 
URI
http://hdl.handle.net/11531/88753
Damping local and inter-area oscillations with synchronous compensators: a fundamental study
Palabras Clave

Synchronous compensators, electromechanical oscillations, power system stabilizers
Colecciones
  • Documentos de Trabajo

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias